Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
Braz. dent. sci ; 26(4): 1-10, 2023. ilus, tab
Artículo en Inglés | LILACS, BBO - Odontología | ID: biblio-1523860

RESUMEN

Objective: The aim of this in vitro study w as t o analyze the influence of the titanium dioxide nanotubes i n a self-cure mode polymerization of a dual resin luting agent through push out bond strength and radiopacity tests. Material and Methods: After mixed with a commercial du al self-adhesive resin cement, three concentrations o f tit anium dioxide nanotubes (0.3, 0.6, and 0.9% by weight) we re analyzed in self-curing mode. T he bond strength to bovine root dentin and fi berglass posts was assessed with the push out bond str ength t est and was evaluated in three thirds (cervical, middle and apical) (n=10), followed by failure mode analysis (SEM), and the ISO standard 9917-2 was followed for radiopacity test (n=10). Data were statistically analyzed by one-way ANOVA test, followed by Tukey's test (α=0.05). Results: Reinforced self-adhesive resin cement with 0.6% titanium dioxide nanotubes showed significant difference compared to the control gr oup for push out test (p=0.00158). The modified groups did not s how significant difference among thirds (p=0.782). Radiopacity sh owed higher value for group w ith 0.9% titanium dioxide nanotubes in comparison w ith control group (p<0.001). Conclusion: The addition of titanium dioxide nanotubes to a self-adhesive resin cement increased the bond strength to dentin and radiopacity values in the self-cure polymerization mode (AU)


Objetivo: O objetivo deste estudo in vitro foi analisar a influência de nanotubos de dióxido de titânio na polimerização química de um agente cimentante resinoso dual através de testes de resistência à união e radiopacidade. Material e Métodos: Após misturado com um cimento resinoso auto-adesivo comercial, três concentrações de nanotubos de dióxido de titânio (0,3, 0,6 e 0,9% em peso) foram analisadas. A resistência da união para a dentina da raiz bovina e os pinos de fibra de vidro foi avaliada pelo teste de push-out e avaliada em três terços (cervical, médio e apical) (n = 10), seguido pelo análise de modo de falha (MEV) e a norma ISO 9917-2 foi seguido para teste de radiopacidade (n = 10). Os dados foram analisados estatisticamente pelo teste ANOVA um fator seguido do teste de Tukey (α = 0,05). Resultados: O cimento resinoso auto-adesivo reforçado com nanotubos de dióxido de titânio a 0,6% mostrou diferença significativa em comparação com o grupo controle para teste de push-out (p=0,00158). Os grupos modificados não mostraram diferença significativa entre os terços (p=0,782). A radiopacidade mostrou maior valor para o grupo com nanotubos de dióxido de titânio 0,9% em comparação com o grupo controle (p<0,001). Conclusão: A adição de nanotubos de dióxido de titânio a um cimento resinoso auto-adesivo aumentou a os valores de resistência de união à dentina e radiopacidade no modo de polimerização química do agente cimentante (AU)


Asunto(s)
Titanio , Cementos Dentales , Pins Dentales , Nanotubos
2.
Braz. dent. sci ; 25(3): 1-11, 2022. tab, ilus, graf
Artículo en Inglés | LILACS, BBO - Odontología | ID: biblio-1373062

RESUMEN

Objective: This study aimed to evaluate the radiopacity, compressive strength, setting time and bioactivity of Biodentine after modification with Ytterbium Tri-Fluoride (YbF3) in three different concentrations. Material and Methods: Radiopacity was determined using the equivalence in millimeters of aluminum (mm Al) from digital radiographs. Compressive strength was evaluated using a universal testing machine. The initial and final setting times were evaluated using Gillmore needle. The bioactive potential was evaluated using the environmental scanning electron microscope (ESEM) connected with Energy Dispersive X-ray analysis (EDX) and X-ray Diffractometer (XRD) at three different time intervals. pH was measured using a pH-meter. Data were analyzed using one-way ANOVA followed by Tukey's post hoc tests (P≤ 0.05). Results: Radiopacity of Biodentine with 2.5%, 5% and 7.5% YbF3 was significantly higher than unmodified Biodentine (P ≤ 0.05). Unmodified Biodentine showed the highest mean compressive strength values compared to all other groups (p≤ 0.05). The addition of YbF3 to Biodentine has extended the final setting time except for the 2.5% YbF3 group that showed no significant difference compared to the control. All groups showed an alkaline pH at 28 days, ESEM coupled with EDX analysis showed evidence of dense globules of calcium phosphate on the surface indicating enhancement of bioactivity. Conclusion: 2.5% YbF3 can be a promising radiopacifying agent to Biodentine with improvement in radiopacity, bioactive potential and maintaining the setting time and compressive strength at acceptable level as indicated by the ISO standards (AU)


Objetivo: O estudo buscou avaliar a radiopacidade, resistência à compressão, tempo de presa e bioatividade da Biodentina modificada por Trifluoreto de itérbio (YbF3). Materiais e Métodos: YbF3 foi incorporado ao pó de Biodentina e dividido em 4 grupos (X0, X1, X2 e X3) de acordo com a concentração de YbF3; 0%, 2.5%, 5% e 7.5% do peso, respectivamente. Os espécimes foram preparados para cada experimento com um total de 40 espécimes para cada teste (n=10 por grupo). A radiopacidade foi determinada através do uso equivalente em milímetros de alumínio. A resistência a compressão foi avaliada através do uso de uma máquina de teste universal. O tempo inicial e final foi avaliado através de uma agulha de Gillmore. O potencial bioativo foi avaliado através do Microscópio Eletrônico de Varredura (ESEM), conectado com a análise de espectroscopia de raios X por energia dispersiva (EDX) e difração de raio X (DRX). O pH foi mensurado através do uso de um pHmetro. Os dados foram analisados pelo ANOVA seguido do Test Tukey. Resultados: A radiopacidade nos grupos X1, X2 e X3 foi significantemente maior do que no grupo X0. O grupo X0 mostrou a maior resistência à compressão comparado com os outros grupos. A adição de YbF3 a Biodentina excedeu o tempo final exceto pelo grupo X1, que não apresentou diferença estatística significante quando comparado com o grupo X0. Todos os grupos apresentaram um pH alcalino com 28 dias. ESEM com análise EDX mostrou evidência de densos glóbulos de fosfato de cálcio na superfície, indicando uma melhora na bioatividade. Conclusão: 2.5% YbF3 é um promissor radiopacificador para Biodentina, que aumentou a radiopacidade e potencial bioativo enquanto manteve o tempo definido e a resistência à compressão em níveis aceitáveis como indica a norma ISO.(AU)


Asunto(s)
Iterbio , Medios de Contraste , Materiales Dentales , Odontología
3.
São José dos Campos; s.n; 2021. 83 p. ilus, graf, tab.
Tesis en Portugués | LILACS, BBO - Odontología | ID: biblio-1362515

RESUMEN

Os cimentos biocerâmicos possuem diversas aplicações clinicas na área de endodontia. Este estudo teve como objetivo avaliar a ação antimicrobiana do cimento de cinco óxidos minerais "5MO", do agregado trióxido mineral "MTA" que já é um material consagrado, como também do agregado trióxido mineral reparador de alta plasticidade "MTA HP", e comparar a capacidade dos mesmos na eliminação de microrganismos anaeróbios, comumente encontrados em infecções endodônticas primárias por meio de teste de MTT; avaliar e comparar também a biocompatibilidade dos mesmos através testes de citotoxicidade de MTT sobre cultura de macrófagos de camundongos (RAW 264.7) e osteoblastos (MG-63); avaliar a composição química dos mesmos através da microscopia eletrônica de varredura "MEV" acoplada a espectroscopia de raios X por dispersão em energia "EDS ou EDAX" e avaliar a fase por difração de raios-X "DRX"; além de avaliar a sua radiopacidade. Neste estudo, foi observada a atividade antibiofilme efetiva dos grupos experimentais sobre alguns microrganismos anaeróbios incluindo Porphyromonas gingivalis, Porphyromonas endodontalis, Parvimonas micra, Fusobacterium nucleatum e Prevotella intermedia, por outro lado, os mesmos foram biocompatíveis sobre os macrófagos e osteoblastos após 5 min de contato. Além disso, foram encontrados principais componentes químicos em que a presença de titânio, enxofre e potássio e a ausência de tungstênio no 5MO o torna diferente do MTA e do MTA HP, e a presença de estrôncio no MTA HP o torna diferente do 5MO e do MTA. Todos os biocerâmicos avaliados apresentaram uma radiopacidade adequada para serem utilizados clínicamente de acordo com o protocolo para radiopacidade de materiais dentários, publicado pela International Standards Organization (ISO). Sendo assim, os cimentos biocerâmicos 5MO, MTA HP, e MTA possuem ação antimicrobiana efetiva contra todos os microrganismos anaeróbios analisados, são biocompatíveis, possuem componentes químicos em comum, e possuem radiopacidade adequada para o uso clínico de material dentário.


Bioceramic cements have several clinical applications in endodontics. This study aimed to evaluate the antimicrobial action of the cement of five mineral oxides "5MO", mineral trioxide aggregate "MTA" which is already an established material, as well as the mineral trioxide aggregate repair high plasticity "MTA HP", and to compare their ability to eliminate anaerobic microorganisms, commonly found in primary endodontic infections by means of MTT test; to evaluate and compare their biocompatibility through MTT cytotoxicity tests on mouse macrophage cultures (RAW 264.7) and osteoblasts (MG-63); evaluate their chemical composition through scanning electron microscopy "SEM" coupled with energy dispersion X-ray spectroscopy "EDS or EDAX" and evaluate the phase by X-ray diffraction "XRD"; in addition to evaluating its radiopacity. In this study, all tested bioceramic cements were effective over some anaerobic microorganisms including Porphyromonas gingivalis, Porphyromonas endodontalis, Parvimonas micra, Fusobacterium nucleatum and Prevotella intermedia, on the other hand, they were biocompatible on macrophages and osteoblasts after 5 minutes of contact. In addition, main chemical components were found in which the presence of titanium, sulfur and potassium and the absence of tungsten in 5MO makes it different from MTA and MTA HP, and the presence of strontium in MTA HP makes it different from 5MO and MTA. All evaluated bioceramic cements presented adequate radiopacity to be used clinically according to the protocol for radiopacity of dental materials, published by the International Standards Organization (ISO). Thus, 5MO, MTA HP, and MTA bioceramic cements have effective antimicrobial action against all tested anaerobic microorganisms, are biocompatible, have chemical components in common, and have adequate radiopacity for the clinical use of dental material.


Asunto(s)
Animales , Ratones , Materiales Biocompatibles , Cementos Dentales , Antiinfecciosos , Antibacterianos , Difracción de Rayos X , Microscopía Electrónica de Rastreo , Materiales Dentales
4.
Rev. odontol. UNESP (Online) ; 48: e20190053, 2019. tab, graf, ilus
Artículo en Portugués | LILACS, BBO - Odontología | ID: biblio-1043178

RESUMEN

Resumo Introdução Dentes artificiais têm sido utilizados para a prática odontológica e, segundo seus fabricantes, apresentam muita similaridade aos dentes humanos para treinamento. Objetivo Avaliar a radiopacidade de dentes endodônticos artificiais para uso em atividades de ensino e saber a percepção de docentes quanto à análise radiográfica. Material e método Trinta réplicas de incisivos centrais superiores de três marcas comerciais (Fábrica de Sorrisos, IM do Brasil e Real Dent) e um incisivo humano foram utilizados. Foram dispostos sobre um sensor radiográfico o dente humano e um dente artificial de cada empresa. As análises de radiopacidade foram feitas no programa Photoshop® em triplicata em quatro regiões distintas: porção central da coroa e nos terços cervical, médio e apical do canal. A percepção quanto à utilização dos dentes como instrumento prático de ensino foi avaliada por meio de um questionário aplicado a oito professores de endodontia. Para análise estatística dos valores de radiopacidade, foi utilizada a ANOVA, seguida do teste de Tukey. Foi empregado um nível de significância de 5%. Para análise do questionário, foram empregados métodos descritivos e por porcentagem de dados no que se refere à frequência das respostas. Resultado Houve diferença de radiopacidade entre os diferentes dentes testados em cada região analisada (p > 0,05). Na percepção dos professores com relação à utilização dos dentes no ensino, eles colocaram em ordem crescente os seguintes dentes para uso: IM do Brasil, Fábrica de Sorrisos, Real Dent e humano. Conclusão A radiopacidade dos dentes artificiais foi diferente do humano. O dente artificial da Fábrica de Sorrisos apresentou os maiores valores de radiopacidade. Contudo, os professores consideraram ideais para utilização no ensino apenas o dente humano e o dente da Real Dent.


Abstract Introduction Artificial teeth have been used for dental practice which, acoording to their manufactures, bear much similarity to human teeth for training. Objective To evaluate radiopacity of artificial endodontic teeth for use in teaching activities and to know the perception of teachers regarding radiographic analysis. Material and method Thirty replicates of upper central incisors of three trade marks (Fábrica de Sorrisos, IM do Brasil and Real Dent) and a human incisor were used. On a radiographic sensor, human tooth and one artificial tooth of each marks were arranged. Radiopacity analyzes were performed using Photoshop® in triplicate in four distinct regions: central portion of the crown and in the cervical, middle and apical thirds of the canal. The perception about the use of teeth as a practical teaching instrument was evaluated through a questionnaire applied to eight teachers of Endodontics. For statistical analysis of the radiopacity values ​​ANOVA was used, followed by the Tukey test. Significance level of 5%. For the analysis of the questionnaire were used descriptive methods and percentage of data regarding the frequency of responses. Result There was a difference in radiopacity between the different teeth tested, in each region analyzed (P > 0.05). In the teachers' perception regarding the use of teeth in teaching, the teachers placed the following teeth for use: IM do Brasil, Fábrica de Sorrisos, Real Dent and human. Conclusion The radiopacity of the artificial teeth was different from the human teeth. The artificial tooth of the Fábrica de Sorrisos presented the highest values ​​of radiopacity. The teachers considered ideal for use in teaching only the human teeth and the prototype Real Dent.


Asunto(s)
Diente Artificial , Rayos X , Educación en Odontología , Endodoncia , Diente , Encuestas y Cuestionarios
5.
Braz. dent. sci ; 21(2): 164-171, 2018. tab, ilus
Artículo en Inglés | LILACS, BBO - Odontología | ID: biblio-906062

RESUMEN

Objective: This study compared the radiopacity of different ceramic systems by means of digital radiographs and evaluate the chemical composition of the samples by Raman spectroscopy. The hypothesis tested was that there was a difference in radiopacity among the tested materials. Material and Methods: Specimens were prepared for each ceramic tested: FLD - VM7 (VITA Zahnfabrik), LD - IPS Empress e.max Press (IPS Empress), AL - In Ceram Alumina (VITA Zahnfabrik), ALYZ - In Ceram Zirconia (VITA Zahnfabrik), YZ - Lava All Ceram (3M/ESPE), and MYZ - Zirconzahn (Talladium Brazil). The specimens were radiographed and submitted to radiographic density readings using a histogram tool. The spectrometer coupled to a petrographic microscope was used for Raman spectroscopy measurements. Analysis of variance (ANOVA) and a Tukey post-hoc test were used to compare radiopacity of the different materials. Results: For all tested materials, the radiopacity showed statistically significant differences, except YZ and MYZ. Lava All Ceram and ZirkonZahn had high radiopacity values and VM7 and IPS Empress e.max Press showed lower radiopacity than human dental structures. Conclusion: It was possible to conclude that radiopacity is closely linked to ceramic chemical composition. (AU)


Objetivo: Este estudo comparou a radiopacidade de diferentes sistemas cerâmicos por meio de radiografias digitais e avaliou a composição química das amostras por espectroscopia Raman. A hipótese testada foi que haveria diferença na radiopacidade entre os materiais testados. Material e Métodos: Os espécimes foram preparados para cada cerâmica testada: FLD - VM7 (VITA Zahnfabrik), LD - Impressora IPS Empress e.max (IPS Empress), AL - Em Ceram Alumina (VITA Zahnfabrik), ALYZ - In Ceram Zirconia (VITA Zahnfabrik), YZ - Lava All Ceram (3M / ESPE) e MYZ - Zirconzahn (Talladium Brasil). Os espécimes foram radiografados e submetidos a leituras de densidade radiográfica utilizando uma ferramenta de histograma. O espectrômetro acoplado a um microscópio petrográfico foi utilizado para medidas de espectroscopia Raman. Análise de variância (ANOVA) e teste post-hoc de Tukey foram usados para comparar a radiopacidade dos diferentes materiais. Resultados: Para todos os materiais testados, a radiopacidade apresentou diferenças estatisticamente significantes, exceto YZ e MYZ. Lava All Ceram e ZirkonZahn apresentaram altos valores de radiopacidade e o VM7 e o IPS Empress e.max Press apresentaram menor radiopacidade do que as estruturas dentais humanas. Conclusão: Foi possível concluir que a radiopacidade está intimamente ligada à composição química da cerâmica. (AU)


Asunto(s)
Odontología , Intensificación de Imagen Radiográfica , Análisis Espectral
6.
Full dent. sci ; 8(30): 130-135, 2017. tab, ilus, graf
Artículo en Portugués | BBO - Odontología | ID: biblio-909963

RESUMEN

A radiopacidade e especificação foram avaliadas de acordo com a norma padrão ISO6876/2001. Para a análise da radiopacidade, 10 placas acrílicas foram confeccionadas com seis furos, cada um com 10,0 mm de diâmetro e 2,0 mm de espessura, e preenchidos com cinco cimentos estudados: AH Plus, Endofill, EndoREZ, Sealapex e MTA Fillapex, e como controle foi utilizada guta-percha. Imagens radiográficas digitais dos espécimes foram importadas do software Digora 1.51. Um densitômetro de alumínio foi utilizado como um instrumento de medição da densidade radiográfica na comparação das amostras, e o valor da radiopacidade foi determinado de acordo com essa densidade radiográfica (mmAl). Os resultados foram analisados estatisticamente por Kruskal-Wallis e complementados por StudentNewman-Keuls. Os cimentos testados apresentaram diferenças estatisticamente significativas entre eles (p<0,05). Os valores da radiopacidade dos cimentos em ordem decrescente em escala de alumínio foram os seguintes: AH Plus (14.86), Sealapex (13.50), Endofill (12.87), MTA Fillapex (11.90) e EndoREZ (10.27). Concluiu-se que a maior radiopacidade ocorreu no cimento AH Plus, porém, todos os materiais testados preencheram os requisitos das normas ISO 6876/2001 (AU).


Specification and radiopacity were evaluated according to standard ISO 6876/2001. For the analysis of radiopacity, 10 acrylic plates were made with six holes, each with 10.0 mm diameter and 2.0 mm thick, and filled with the five studied cements: AH Plus, Endofill, EndoREZ, Sealapex, MTAFillapex, and a control guta-percha was used. Digital radiographic images of the specimens were imported from Digora software version 1.51. An aluminum densitometer was used as an instrument for measure the radiographic density in the comparison sample, and the value of optical density was determined in accordance with this radiographic density (mm Al). The results were statistically analyzed using Kruskal-Wallis test and complemented by Student-Newman-Keuls test. The tested cements showed significant statistically differences between them (p < 0.05). The values of the radiopacity of the cement in decreasing scale aluminum were the following: AH Plus (14.86), Sealapex (13.50), Endofill (12.87), MTA Fillapex (11.90), and EndoREZ (10.27). It was concluded that most radiopacity occurred in AH Plus cement, however, all materials tested met the requirements of ISO 6876/2001 standards (AU).


Asunto(s)
Estudio Comparativo , Cementos Dentales , Intensificación de Imagen Radiográfica/instrumentación , Estadísticas no Paramétricas
7.
RFO UPF ; 19(2): 166-171, maio/agosto 2014.
Artículo en Portugués | LILACS-Express | LILACS | ID: lil-737234

RESUMEN

Objetivo: o presente estudo tem por objetivo avaliar a influência da adição de diferentes concentrações de subnitrato de bismuto (SN) nas propriedades de mate-riais para base protética. Materias e método: foi adicio-nada 0%, 1%, 2%, 5%, 10% e 20% de SN em peso em resina acrílica autopolimerizável da marca Clássico e submetidos aos ensaios de resistência à flexão, micro-dureza Knoop, radiopacidade, análise antimicrobiana, rugosidade e caracterização em micro-Raman. O teste estatístico escolhido foram o ANOVA de uma via e o teste de comparações múltiplas de Tukey. O nível de significância foi de 5% para todos os testes. Resultados: os resultados de resistência à flexão atingiram valores acima do recomendado pela ISO 1567. Quanto maior a concentração da carga de SN maior o valor de mi-crodureza Knoop, sendo estatisticamente significativo em 10% e 20% (p<0,001); os resultados da rugosidade mostraram valores abaixo do limiar, 0,2 µm. A adição de subnitrato de bismuto não obteve um potencial an-timicrobiano, mas apresentou uma maior radiopacida-de, (p<0,001). Conclusão: diante dos dados, conclui-se que a adição da carga de SN influencia nas proprie-dades mecânicas de resina acrílica significativamente, destacando-se que a radiopacidade desse material faci-lita a sua remoção quando ingerida ou aspirada.

8.
Full dent. sci ; 5(18): 360-367, abr. 2014. ilus, tab, graf
Artículo en Portugués | LILACS, BBO - Odontología | ID: lil-716619

RESUMEN

A radiopacidade ‚ uma das propriedades essenciais dos cimentos obturadores endodônticos, pois permite ao profissional avaliar a qualidade da obturação de canais radiculares e, consequentemente, a previsibilidade do tratamento. As especificações de radiopacidade foram avaliadas de acordo com a norma ISO 6876/2001. Para a análise da radiopacidade, 10 placas acrílicas foram confeccionadas com seis cavidades, cada uma com 5,0 mm de diâmetro e 2,0 mm de espessura e preenchidas com os cinco cimentos estudados: AHPlus, Endofill, Fill Canal, Sealapex, Sealer 26 e, como controle, foi utilizada guta-percha. Imagens radiográficas digitais dos espécimes foram importadas do software Digora for Windows versão 1.51. Uma escala de alumínio foi utilizada como um instrumento de medição da densidade radiográfica na comparação das amostras, e o valor da radiopacidade foi determinado de acordo com essa densidade radiográfica (mm Al). Os resultados foram analisados estatisticamente por teste ANOVA e complementados por Tukey. Os cimentos testados apresentaram diferenças estatisticamente significantes entre eles (p<0,005). Os valores da radiopacidade dos cimentos em ordem decrescente foram os seguintes: AHPlus (13,456ñ 0,069); Sealer 26 (11,197ñ0,039); Endofill (11,050ñ0,016); Fill Canal (9,793ñ0,074) e Sealapex (7,604ñ0,057). A radiopacidade da guta-percha (10,912ñ0,054) foi menor que o AHPlus, Sealer 26 e Endofill, por‚m todos os materiais testados preencheram os requisitos das normas ISO 6876/2001


Radiopacity is an essential attribute of endodontic filling materials because it allows an evaluation of the root canal filling, and thus the predictability of the treatment. Radiopacity was evaluated according to ISO 6876/2001 standards. For radiopacity analysis, ten acrylic plates were made, each with six holes 10.0 mm diameter and 2.0 mm thickness which were filled with the five studied cements: AHPlus, Endofill, Fill Canal, Sealapex, Sealer 26 and, as control was used guta-percha. Digital radiographic images of the patients were imported into the software Digora for Windows version 1.51. An aluminum step wedge was used to measure the radiographic density in the comparison of the samples. The radiopacity value was determined according to radiographic density (mm Al). The studied cements have presented statistically significant differences among them (p<0.005). Radiopacity values of the cements in descending order were: AHPlus (13.456ñ0.069); Sealer 26 (11.197ñ0.039); Endofill (11,050ñ0,016); FillCanal (9,793ñ0,074); and Sealapex (7.604ñ0.057). The radiopacity of guta-percha (10.912ñ0.054) was lower than AHPlus, Sealer 26 and Endofill, however all the tested materials were in accordance with the ISO 6876 normative


Asunto(s)
Cementos Dentales/química , Materiales de Obturación del Conducto Radicular/uso terapéutico , Radiografía Dental Digital/métodos
9.
Full dent. sci ; 4(13): 207-211, out.-dez. 2012. ilus, tab, graf
Artículo en Portugués | LILACS, BBO - Odontología | ID: lil-681694

RESUMEN

A radiopacidade dos materiais utilizados em restaurações ou como base forradora exerce importância devido ao contraste da visualização com as estruturas do dente. A norma internacional ISO 4049:2009 qualifica o teste para a quantificação da radiopacidade das resinas compostas. Materiais restauradores devem ser mais radiopacos do que a estrutura do dente e ter exequibilidade para distinguir de lesões cariosas ou dentina descalcificada. As imagens das amostras dos materiais restauradores foram projetadas e importadas para o software Digora para Windows versão 1.51 (Orion Corporation), onde uma ferramenta relacionou tons de cinza nas diversas áreas com a densidade radiográfica. Para isso, estudos que envolvam esta propriedade devem utilizar como padrão uma escala de alumínio. Cinco matrizes de acrílico foram confeccionadas, cada uma com 6 cavidades com formato circular de tamanho 5,0 mm de diâmetro e com 2,0 mm de espessura, onde foram inseridos seis marcas de resinas compostas. A radiopacidade não depende somente da quantidade da carga, mas também do teor dos aditivos radiopacos na carga inorgânica. A maioria das resinas permite uma boa visualização no diagnóstico radiográfico. A radiopacidade da resina depende da quantidade de BaO no complexo do silicato de bário-alumínio


The radiopacity of the materials used in restorations or as a base liner is important to visualize the contrast to the structures of the tooth. ISO 4049:2009 International Standard describes the test to quantify the radiopacity of composite resins. Restorative materials should be more radiopaque than the tooth structure to distinguish easily decalcified dentin or carious lesions. The images of samples of restorative materials were designed and imported into the software Digora for Windows version 1.51 (Soredex Orion Corporation, Helsinki, Finland), where a tool related grayscale in various areas with the radiographic density. For this reason, studies involving this property should use a default scale of aluminum. Five casts were made from acrylic resin, each with 6 circular shaped cavities with a size of 5.0 mm in diameter and 2.0 mm thickness where in six brands of composite resins were inserted. The radiopacity depends not only on the amount of charge, but also on the content of the radiopaque additives in the inorganic filler. Most resins allow good visualization in radiographic diagnosis. The radiopacity of the resin depends on the quantity of BaO in the complex of barium aluminum silicate


Asunto(s)
Materiales Dentales/química , Radiografía Dental , Resinas Compuestas/química , Análisis de Varianza
10.
Rev. Salusvita (Online) ; 31(2)2012. graf, ilus, tab
Artículo en Portugués | LILACS | ID: lil-689455

RESUMEN

Objetivo: O presente estudo tem como objetivo avaliar a radiopacidade de três materiais utilizados como retrobturadores. Métodos: Foram avaliados a radiopacidade de três cimentos: Sealer 26, Cimento Portland e Fillapex associado com 50% de cimento Portland.Para a determinação da radiopacidade, foram confeccionados corpos de provas cilíndricos de 10 mm de diâmetro e 1 mm de altura com os cimentos em teste e cilindros de dentina de mesma espessura, de acordo com a norma ISO 6876:2001. Após a sensibilização e processamento das películas, as imagens foram digitalizadas e analisadas quanto a densidade radiográfica no programa Digora 1.51. O valor da radiopacidade foi determinado em densidade radiográfica que foi, também, convertida em milímetros de alumínio (mm Al). Resultados: Os resultados demonstraram que o Sealer 26 possui maior radiopacidade, seguido pelo Fillapex associado com 50% de Cimento Portland e o cimento Portland. Conclusão: Conclui-se que todos os materiais apresentaram radiopacidade maior que a dentina e as normas da ISO, com exceção do cimento Portland.


Aim: The present study aims to evaluate the radiopacity of three used as root-end filling materials. Methods: To evaluated the radiopacity of three cement: Sealer 26, Fillapex associated with 50% of Portland cement and Portland cement. For the determination of radiopacity, cylindrical specimens with 10 mm in diameter and 1mm in thickness were made with the cements under test and dentin cylinders of equal thickness, according to ISO 6876:2001. After the raising and processing of films, the images were digitized andanalyzed for the radiographic density in Digora 1.51. The value of radiopacity was determined in radiographic density that was also converted into millimetres of aluminium (mm Al). Results: The results showed that the Sealer 26 has greater radiopacity, followed by Fillapex associated with 50% of Portland cement and Portland cement. Conclusion: It is concluded that all materials presented radiopacity is greater than the dentin and the ISO standards, with the exception of Portland cement.


Asunto(s)
Cementos Dentales/análisis , Endodoncia , Odontología
11.
Full dent. sci ; 2(6): 208-212, 20110816.
Artículo en Portugués | LILACS, BBO - Odontología | ID: biblio-850837

RESUMEN

Avaliar o grau de radiopacidade do cimento do hidróxido de cálcio prognostica se essa propriedade pode asseverar como fator significativo. As imagens radiográficas foram digitalizadas e analisadas por um sistema de programa computadorizado. O objetivo deste estudo é avaliar, pelo software Digora que permite a manipulação da imagem, as radiografias tomadas de três marcas comerciais de cimentos de hidróxido de cálcio (Hidro C, Hydcal e Liner) com espessura de 2mm e 3,5mm de diâmetro para averiguar a eficácia de cada um como material radiopaco. As amostras de cada cimento foram posicionadas, em sentido paralelo ao longo do eixo sobre superfície da película de radiografia oclusal. Junto com os espécimes foi colocado o stepwedge de alumínio para ser utilizado como instrumento de medida por comparação. Para tomada das radiografias, utilizou-se um aparelho de raios-X odontológico marca Dabi modelo Image Seletronic HF, regulado para 70kVp e 8mA. A análise de variância a um critério de classificação (p<0,05) revelou que não existem diferenças estatisticamente diferentes entre os cimentos testados


Measure the degree of radiopacity of calcium hydroxide cement predicts whether this property may assert as a significant factor. Radiographs were digitized and analyzed by a computerized scheduling system. The aim of this study is to evaluate, by Digora software that allows the manipulation of the image, the radiographs taken of three different brands of calcium hydroxide cement (Hydro C, Hydcal and Liner) with a thickness of 2mm and 3.5 mm in diameter to determine the effectiveness of each as a radiopaque material. The samples of each cement were placed in parallel direction along the axis on the film surface occlusal radiography. Along with the specimens the stepwedge aluminum was placed to be used as a measuring instrument by comparison. To take the radiographs, we used an X-ray machine dental Dabi Image Seletronic HF model, set to 70kVp and 8mA. The analysis of variance with a criterion of classification (p <0.05) revealed no statistically different between the tested cements


Asunto(s)
Cementos Dentales , Hidróxido de Calcio/química , Procesamiento de Imagen Asistido por Computador , Ensayo de Materiales/métodos , Análisis de Varianza , Radiografía Dental Digital/métodos
12.
Rev. odonto ciênc ; 26(4): 326-330, 2011. ilus, tab
Artículo en Inglés | LILACS, BBO - Odontología | ID: lil-625017

RESUMEN

PURPOSE: To simulate soft and hard tissues to assess radiopacity of three root canal sealers (Endofill, AH Plus and Sealer 26). METHODS: Five circular specimens (10x1 mm) were made and three experimental conditions were created. Situation #1: an aluminum step wedge allowed specimen being submitted to three digital radiographs. Situation #2: a retromolar mandibular segment containing the specimen was positioned between the digital sensor and X-ray machine. Situation #3: a soft tissue simulating material (utility wax - 30 mm) was associated with the mandibular segment. Mean gray values were measured using ImageTool 3.0 software. Two-way ANOVA and Tukey's test (α=0.05) was performed. RESULTS: Radiopacity increased when bone tissue was used (P<0.05), except for AH Plus. Situation #3 provided greater radiopacity (P<0.05). Radiopacity between most and least sealers decreased 44% when Situation #1 and #3 were compared. CONCLUSION: Simulated soft and hard tissues influenced the radiopacity of root canal sealers.


OBJETIVO: Simular tecidos moles e duros para avaliar a radiopacidade de três cimentos endodônticos. METODOLOGIA: Cinco espécimes circulares (10x1 mm) foram confeccionados e três situações experimentais foram criadas. Situação #1: espécime e uma escala de alumínio foram submetidos a 3 tomadas radiográficas digitais. Situação #2: um segmento retromolar de uma mandibula humana contendo o espécime foi posicionada entre o aparelho de raio X e o sensor digital. Situação #3: um simulador de tecido mole (cera utilidade - 30 mm) foi associado ao segmento mandibular. A média dos valores de cinza foi medida através do programa ImageTool 3.0. Análise de variância de dois critérios e Teste de Tukey (α=0.05) foram realizados para análise estatística. RESULTADOS: A radiopacidade aumentou quando tecido ósseo foi usado (P<0.05), exceto para o Ah Plus. A Situação #3 proporcionou os maiores valores de radiopacidade (P<0.05). Os valores de radiopacidade entre o cimento mais e o menos radiopaco diminuiu 44% quando as situações #1 e #3 foram comparadas. CONCLUSÃO: A simulação de tecidos moles e duros influencia a radiopacidade de cimentos endodônticos.


Asunto(s)
Interpretación Estadística de Datos , Cementos Dentales , Radiografía Dental Digital/métodos
13.
RSBO (Impr.) ; 7(4): 389-395, out.-dez. 2010.
Artículo en Portugués | LILACS-Express | LILACS | ID: lil-564411

RESUMEN

Introdução: O cimento Sealer 26® contém resina epóxi associada aohidróxido de cálcio, apresentando menor radiopacidade que algunscimentos endodônticos. Com o intuito de melhorar essa propriedade,tem-se agregado iodofórmio ao pó do cimento. Entretanto, aoexecutar tal procedimento, desconhecem-se as possíveis alteraçõesnas propriedades físicas e químicas do material. Objetivo: Avaliar acapacidade de selamento marginal apical, a solubilidade e o pH doSealer 26® puro ou acrescido de iodofórmio em diversas proporções.Material e métodos: Foram manipuladas e submetidas ao teste desolubilidade três associações experimentais de Sealer 26®, puroou acrescido de iodofórmio. Paralelamente, as combinações foraminseridas em tubos de polietileno e imersas em água destilada, e opH das soluções foi avaliado nos períodos de 24 horas e 7 dias. Emseguida, 40 raízes de incisivos inferiores extraídos, subdivididosem quatro grupos de dez espécimes cada, foram retrobturados comuma das misturas anteriormente descritas. Imergiram-se as raízesem Rhodamine B, sob vácuo, por 72 horas. Concluída a imersão,os espécimes foram desgastados longitudinalmente, os fragmentosradiculares fotografados, as imagens digitalizadas e a infiltração apicalmedida pelo programa Image Tool. Os dados obtidos foram submetidosa análise estatística, com nível de significância de 5%. Resultados:Os testes de infiltração e solubilidade não demonstraram diferençasentre os grupos experimentais (p > 0,05). A análise do pH apresentoudiferença apenas no período de 24 horas entre o grupo do Sealer 26®puro e o grupo com 1,1 g de iodofórmio (p < 0,05). Conclusão: Aadição de iodofórmio ao Sealer 26®, nas proporções descritas, nãoalterou as propriedades de selamento marginal apical, a solubilidadenem o pH do cimento original


Introduction: Sealer 26® cement contains bisphenol epoxy resinassociated with calcium hydroxide, presenting smaller radiopacity thanother endodontic cements. Aiming to improve this property, iodoformhas been added in its composition. However, this addition?s possiblechanges in physical and chemical properties still need to be studied.Objective: To evaluate the apical sealing ability, solubility, and pH ofSealer 26® alone or with iodoform, at several proportions. Material andmethods: Three experimental mixtures of Sealer 26®, alone or withiodoform, were prepared and subjected to solubility test. Additionally,these combinations were inserted into polyethylene tubes and immersedin distilled water, and, their pH was evaluated after 24-h and 7-dayperiods. Subsequently, forty roots of extracted lower incisors subdividedinto four groups of 10 specimens each, were retrograde filled with oneof the previously described mixtures and gutta-percha points. The rootswere immersed in Rhodamine B, under vacuum, for 72 hours. Afterthis period, the specimens were longitudinally sectioned, root fragmentsphotographed, these images scanned, and apical infiltration measuredby Image tool software. The obtained data were subjected to statisticalanalysis, at a significance level of 5%. Results: Marginal leakage andsolubility tests did not show any difference among the experimentalgroups (p > 0.05). pH analysis was only statistically different at 24-h period and between Sealer 26® alone and 1.1g iodoform group(p < 0.05). Conclusion: The presence of iodoform in Sealer 26®, at theused proportions, did not alter the solubility, apical marginal leakageand pH properties of the original cement.

14.
Rev. odonto ciênc ; 25(1): 74-77, jan.-mar. 2010. ilus, graf
Artículo en Inglés | LILACS, BBO - Odontología | ID: biblio-874069

RESUMEN

Purpose: To evaluate the radiopacity produced by seven commercially available (AH Plus, Epiphany, Sealapex, Acroseal, Sealer 26, Endomethasone and Endofill) and one experimental (MBP) root canal sealers. Methods: Sealer radiopacity testing was performed according to ANSI/ADA Specification No. 57. Specimens were radiographed with an aluminum stepwedge, and the resulting images were digitalized. Radiographic densities expressed in Aluminum mm (mm Al) were compared using an ANOVA and Tukey test (alpha=0.05). Results: AH Plus (10 mm Al) and Epiphany (9.0 mm Al) were the most radiopaque root canal sealers, followed by Sealapex (8 mm Al), Endofill (7 mm Al), Endomethasone (7 mm Al), MBP (7 mm Al) and Sealer 26 (6 mm Al). Acroseal (5 mm Al) showed the smallest radiopacity among the tested sealers (P<0.05). Conclusion: The radiopacities of the tested sealers were above the minimum level recommended by ANSI/ADA Specification No. 57.


Objetivo: Avaliar a radiopacidade produzida por sete cimentos comercialmente disponíveis (AH Plus, Epiphany, Sealapex, Acroseal, Sealer 26, Endomethasone and Endofill) e um em estágio experimental (MBP). Metodologia: Depois de homogeneizados os materiais, o teste de radiopacidade foi executado conforme a especificação no 57 da ANSI/ADA. Radiografou-se os espécimes junto a uma escala de Alumínio e as imagens resultantes foram digitalizadas. As densidades radiográficas expressas em milímetros de Alumínio (mm Al) foram comparadas por meio da análise de variância e teste de Tukey (alfa=0.05). Resultados: Os cimentos AH Plus (10 mm Al) e Epiphany (9 mm Al) apresentaram as maiores radiopacidades seguidos pelo Sealapex (8 mm Al), Endofill (7 mm Al), Endométhasone (7 mm Al), MBP (7 mm Al) e Sealer 26 (6 mm Al). Acroseal (5 mm Al) mostrou a menor radiopacidade entre os cimentos testados (P<0.05). Conclusão: Concluiu-se que as diferentes radiopacidades dos cimentos testados estão acima do nível mínimo recomendado pela especificação nº 57 da ANSI/ADA.


Asunto(s)
Humanos , Cementos Dentales/química , Radiografía Dental Digital , Materiales de Obturación del Conducto Radicular
15.
Odontol. clín.-cient ; 9(1): 25-32, jan.-mar. 2010. ilus
Artículo en Portugués | LILACS, BBO - Odontología | ID: lil-541603

RESUMEN

Radiopacidades em tecidos moles da região bucomaxilofacial são comuns e aparecem geralmente nos exames radiográficos de rotina. Verifica-se, no entanto, a dificuldade do cirurgião-dentista na identificação dessas imagens. As mais frequentes calcificações descritas na literatura são os ateromas de artéria carótida, os flebolitos, os sialolitos, as calcificações de nódulos linfáticos, os tonsilolitos, os antrolitos e os rinolitos e as calcificações do complexo estilohioideo. Realizou-se uma revisão sistemática de literatura das características radiográficas das calcificações em tecidos moles da região de cabeça e pescoço com o objetivo de auxiliar o profissional na identificação de tais condições patológicas. Outros exames imaginológicos, como a tomografia computadorizada, a ultrassonografia e a ressonância magnética, também são importantes para o diagnóstico, porém não são imprescindíveis. Grande parte dos artigos encontrados são relatos de caso clínico. Concluiu-se que os profissionais devem estar atentos à presença dessas radiopacidades nas radiografias odontológicas e basear-se, também, em dados clínicos para um correto diagnóstico dessas alterações.


Ordiinary radiographic examinations of soft tissues in the maxilofacial region usually show radiopacities. It is remarkable, however, the difficult of the dentist about these images identification. The most frequent calcifications descript on literature are the carotid atheromas, the phleboliths, the sialoliths, cervical node calcifications, the tonsiloliths, the abtroliths and the rinoliths and stylohyoid complex calcifications. A systematic review on literature about head and neck soft tissues calcifications radiological characteristics was made with the objective of helping on the identification of such pathological conditions. Other imaginologics exams like computed tomography, ultrasound and the magnetic resonance are also important for diagnosis but not necessary. Most of the articles found are clinical reports. The conclusion is that the dentist must be aware to the presence of these radiopacities on odontological radiographics and also be based on clinical data for a correct diagnosis of these alterations.


Asunto(s)
Calcinosis , Traumatismos de los Tejidos Blandos , Osificación Heterotópica
16.
Porto Alegre; s.n; 2010. 46 p. graf, tab.
Tesis en Portugués | LILACS, BBO - Odontología | ID: lil-553233

RESUMEN

A radiopacidade dos materiais restauradores deve permitir distinguí-los da estrutura dental. Os adesivos dentinários normalmente, não possuem radiopacidade satisfatória a qual pode ser buscada com o acréscimo de substâncias que apresentem essa característica. Entretanto, esses materiais não devem interferir negativamente nas propriedades do polímero formado. O objetivo deste estudo foi avaliar a influência da adição de substâncias radiopacificantes em uma resina adesiva experimental nas propriedades do polímero. Uma resina adesiva experimental foi formulada com 50 % de Bis-GMA, 25 % TEGDMA, e 25 % HEMA, em peso, acrescido de Canforoquinona e EDAB (1% /mol). Para formar os grupos experimentais seis substâncias foram adicionadas à resina base: dióxido de titânio, óxido de bismuto, sulfato de bário, quartzo, dióxido de zircônio e trifluoreto de itérbio, em diferentes concentrações. A radiopacidade foi avaliada utilizando um sistema digital com placas de fósforo VistaScan (Dürr Dental GmbH & CO. KG, Bietigheim-Bissingen, Alemanha) sendo analisadas através do software DBSWIN 4.5, quanto a densidade radiográfica. As demais propriedades avaliadas foram: grau de conversão através de FTIR; resistência à flexão, baseada na normatização da ISO 4049/2010. Radiopacidade de resinas adesivas experimentais com ao menos 30% sulfato de bário ou óxido de bismuto ou 40% de zircônia apresentaram radiopacidade semelhante a 2mm de alumínio. Resinas adesivas com ao menos 20% de fluoreto de itérbio apresentaram radiopacidade satisfatória (2mm de Al) sem influenciar outras propriedades.


The radiopacity of restorative materials should be sufficient to allow the clinician to distinguish the material from normal and demineralized tissues. It is recognized that unfilled resin adhesives are radiolucent which could be reached with radiopaquing agents’ addition. The aim of this study is to evaluate, in an experimental adhesive resin, the influence of radiopaquing agents at polymer properties. A model adhesive resin was formulated with 50% of Bis-GMA, 25% of TEGDMA, 25% of HEMA in weight, and camphorquinone and EDAB (1%mol). The experimental groups were formed with addition of six radiopaquing agents: titanium dioxide, bismuth oxide, barium sulfate, quartz, zirconium, and ytterbium trifluoride at different concentration. The radiopacity was evaluated using an aluminum step-wedge and VistaScan (Dürr Dental GmbH & CO. KG, Bietigheim-Bissingen, Alemanha) phosphorous plates radiographs digital system and DBSWIN 4.5 software. The other properties evaluated were degree of conversion with FTIR and...


Asunto(s)
Recubrimientos Dentinarios , Ensayo de Materiales , Espectroscopía Infrarroja por Transformada de Fourier , Resistencia a la Tracción
17.
Rev. odonto ciênc ; 24(4): 414-419, Oct.-Dec. 2009. tab, graf
Artículo en Inglés | LILACS, BBO - Odontología | ID: biblio-873970

RESUMEN

Purpose: To evaluate the effect of the addition of three radiopaque agents to an experimental adhesive on conversion kinetics, flexural strength and radiodensity. Methods: The model adhesive was formulated by mixing 50 wt% Bis-GMA, 25 wt% TEGDMA and 25 wt% HEMA. Barium sulfate, Titanium dioxide and Zirconium in 0.1, 0.2, 0.4, 0.8 and 1.6 wt% were added separately resulting in 15 experimental groups and 1 control group. The conversion kinetics of the model adhesive was evaluated using real time Fourier Transform Infrared Spectroscopy. The flexural tests were performed on 5 specimens (12 × 2 × 2 mm) for each group (total n = 80) in a universal testing machine. The radiodensity was evaluated by using an aluminum step-wedge and VistaScan phosphorous plates radiographs digital system with 0.6 s exposure and focal distance of 40 cm. Results: No statistical difference (P > 0.05) was found in flexural strength among all groups. The values of degree of conversion ranged from 45.51% e 62.46%. All groups showed higher values than 0.54 mm of aluminum for the evaluation of radiopacity. Conclusion: The addition of radiopaquing agents increased the adhesive radiodensity and did not affect its degree of conversion and flexural strength.


Objetivo: Avaliar a influência da adição de três substâncias radiopacificadoras na cinética de conversão, resistência à flexão e radiodensidade de um adesivo experimental. Metodologia: O adesivo foi formulado com 50% de Bis-GMA, 25% TEGDMA e 25% HEMA, em peso. Foram adicionados 0,1%; 0,2%; 0,4%; 0,8%; 1,6%, em peso, de Sulfato de Bário, Óxido de Titânio e Dióxido de Zircônia, totalizando 15 grupos experimentais e um grupo controle. A cinética de polimerização foi avaliada por FTIR em tempo real. O ensaio de miniflexão foi realizado com 5 espécimes (12 × 2 × 2 mm) para cada grupo (n total = 80) em uma máquina de ensaios universal. A radiodensidade foi obtida utilizando um sistema digital com placas de fósforo VistaScan, 0,6 s de exposição e distância focal de 40 cm e os valores foram comparados a uma escala de alumínio. Resultados: Não houve diferença estatisticamente significativa no ensaio de miniflexão entre os grupos (P > 0,05). Os valores de grau de conversão ficaram entre 45,51% e 62,46%, enquanto a radiodensidade foi superior a 0,54 mm de alumínio, sem diferença entre os grupos. Conclusão: O acréscimo das substâncias radiopacificadoras aumentou a radiopacidade do adesivo e não alterou o grau de conversão e a resistência à flexão.


Asunto(s)
Recubrimientos Dentinarios/química , Materiales Dentales , Estudios de Casos y Controles , Resistencia a la Tracción
18.
Rev. odonto ciênc ; 23(4): 338-341, out.-dez. 2008. tab
Artículo en Portugués | LILACS, BBO - Odontología | ID: lil-500147

RESUMEN

Objetivo: O presente estudo teve por finalidade analisar a radiopacidade de alguns cimentos endodônticos utilizando um sistema de radiografia digital. Metodologia: Foram testados os cimentos endodônticos AH-Plus, N-Rickert, Endofill, Óxido de zinco e eugenol (OZE) e Intrafill. Seis corpos-de-prova cilídricos (1x0,5cm) para cada cimento foram confeccionados e armazenados a 37ºC e umidade relativa de 100%, durante 72h. Os corpos-de-prova foram posicionados na região central do sensor do sistema digital Kodak RVG 5000 e o cilindro do aparelho radiográfico foi posicionado perpendicularmente a uma distância focal de 5cm, com tempo de exposição de 0,05 segundos. A partir da imagem digital obtiveram-se os valores da densidade óptica em pixels da região central e pontos eqüidistantes à direita e à esquerda de cada corpo-de-prova. Os dados foram analisados por ANOVA e teste de Tukey (α=0,05). Resultados: Houve diferença estatística entre todos os cimentos, com exceção da comparação entre o Intrafill e o Endofill. A radiopacidade dos cimentos em ordem crescente foi: ZOE < Endofill = Intrafill < N-Rickert < AH-Plus. Conclusão: O método de radiografia digital foi sensível para detectar diferenças de radiopacidade entre os cimentos endodônticos analisados.


Purpose: This study aimed to evaluate the radiopacity of some endodontic sealers using a digital radiograph system. Methods: The endodontic sealers tested were: AH-Plus, N-Rickert, Endofill, Óxido de zinco e eugenol (OZE), and Intrafill. Six cylindrical-shaped specimens (1x0.5cm) were fabricated with each material and stored at 37ºC and 100% relative humidity for 72h. Each specimen was placed at the central area of the sensor of the digital system Kodak RVG 5000, and the X-ray cylinder was positioned perpendicularly at a 5cm-focal distance with time of exposure of 0.05s. The digital image software was used to measure optical density in pixels of the specimens at their central area and at the right and left sides. Data were analyzed by ANOVA and Tukey test (α=0.05). Results: There was a statistically significant difference of radiopacity among the tested materials, except for the comparison between Intrafill and Endofill. The level of radiopacity in ascending order was: ZOE < Endofill = Intrafill < N-Rickert < AH-Plus. Conclusion: The digital radiograph method was sensitive to detect differences of radiopacity among the tested endodontic sealers.


Asunto(s)
Cavidad Pulpar , Cementos Dentales , Materiales de Obturación del Conducto Radicular , Radiografía Dental Digital
19.
Rev. Fac. Odontol. Porto Alegre ; 48(1/3): 17-21, 2007.
Artículo en Portugués | LILACS, BBO - Odontología | ID: lil-533977

RESUMEN

A radiopacidade é uma das propriedades físicas requeridas pelos diferentes materiais de uso endodôntico, permitindo avaliar o preenchimentodo sistema de canais radiculares. O objetivo deste estudo foi avaliar a densidade óptica de três pastas de hidróxido de cálcio – hidróxido de cálcio pró-análise (Biodinâmica) + propilenoglicol 400 (Farmácia Extrato Puro), pasta Calen (SS White) e pasta UltraCal XS (UltraDent), associadas a um simulador de tecidos. Foram confeccionados 15 corpos-de-prova a partir de um tubo de polietileno, que originou três grupos experimentais, com cinco tubos preenchidos com cada uma das pastas avaliadas. Com o intuito de averiguar a interferência do tubo utilizado na radiopacidade, foram incluídos como amostras, mais dois grupos; um composto apenas com o dente e outro com um tubo vazio inserido no interior do canal radicular. Foram obtidas 25 imagens digitais padronizadas, utilizando o sistema Visualix, sendo 5 para cada grupo. As imagens foram exportadas para o programa Adobe Photoshop v. 7.0, no qual foi determinada a média e o desvio padrão da densidade óptica em uma área padronizada da imagem, correspondente à posição do tubo. Os valores médios de densidade óptica encontrados foram, em ordem decrescente, pasta UltraCal XS (236,25 ± 2,96), pasta Calen (230,32 ± 3,49) e pasta Pró-análise + Propilenoglicol (210,95 ± 3,29). O sistema Visualix foi capaz de identificar diferentes padrões de radiopacidade para os materiais testados, sendo que todas as pastas apresentaram radiopacidade significativamente maior que a do conduto radicular vazio e diferiram significativamente entre si.


Radiopacity is one of the physical properties requested by the different materials of endodontic use, which evaluate the filling of the pulp canal system. The aim of this study was to evaluate the radiopacity of three calcium hydroxide pastes: calcium hydroxide pro-analysis (biodynamics) + Propilenoglicol 400 (pharmacy pure extract), Calen (SS white) and UltraCal XS (Ultra Dent), associated to a tissue simulator. Fifteen samples were manufactured using a polyethylene tube, originating three experimental groups, with five tubes filled with each one of the pastes evaluated. In order to find out the interference of the tube in the radiopacity, another two groups were included: one composed just by the tooth and other with an empty tube inserted in the root canal. Using the Visuallix system, 25 standardized digital images were obtained (5 of each group). The images were exported to Adobe Photoshop v. 7.0 software, in order to obtain the mean values and standard deviation of gray levels in a standardized area of the image, corresponding to the tube position. The mean values of optic density were, in decreasing order, UltraCal XS (236,25 +2,96), Calen (230,32 + 3,49) and pro-analysis+ propilenoglicol (210,95 + 3,29). The Visualix system was able to identify different patterns of the radiopacity in the tested materials, which were more radiopaque than the empty root canal and significantly different in terms of radiopacity.


Asunto(s)
Hidróxido de Calcio/química , Radiografía Dental Digital , Materiales de Obturación del Conducto Radicular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...